Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(17): e37840, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669412

RESUMO

To investigate the clinical efficacy and knee joint kinematic changes of posterior cruciate ligament (PCL) reconstruction assisted by Chinese knotting technique (CKT). A retrospective analysis was conducted on 88 cases of PCL reconstructive surgery admitted between September 2016 and September 2020. All patients were operated on by the same senior doctor and his team. The patients were divided into 2 groups according to whether the CKT was applied, with 44 cases in each group. Both groups received active rehabilitation treatment after surgery. All patients were followed up for more than 2 years. International knee documentation committee, hospital for special surgery (HSS), and Lysholm scores were used to evaluate the clinical efficacy of the 2 methods at 3, 12, and 24 months after surgery. The motion cycle and kinematic indices of the knee joint were measured by the Opti_Knee three-dimensional motion measurement system before surgery and at 3, 12, and 24 months after surgery. A secondary arthroscopic examination was performed at 12 months after surgery, MAS score was used to evaluate the secondary endoscopic examination of PCL. All the patients had wound healing in stage I without infection. International Knee in both sets Documentation Committee scores, HSS scores and Lysholm scores were gradually improved at all time points (P < .05); compared with the traditional group, the HSS score was higher in the reduction group 12 months after surgery (P < .05), but there was no significant difference at 24 months after surgery. 12 months and 24 months after 3 dimensional motion measurement system using Opti_Knee showed a reduction group before and after displacement and displacement of upper and lower range than the traditional group (P < 0. 05). One year after surgery, the good and good rate of MAS score reduction group was higher than traditional group. CKT assisted PCL reconstruction can improve the subjective function score of the affected knee joint and the results of secondary microscopy. Satisfactory knee kinematic function can be obtained in the early stage, and the anteroposteric relaxation of the knee joint can be reduced.


Assuntos
Reconstrução do Ligamento Cruzado Posterior , Humanos , Estudos Retrospectivos , Masculino , Feminino , Adulto , Reconstrução do Ligamento Cruzado Posterior/métodos , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Resultado do Tratamento , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/cirurgia , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Artroscopia/métodos , Adulto Jovem , Técnicas de Sutura , População do Leste Asiático
2.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(7): 833-838, 2023 Jul 15.
Artigo em Chinês | MEDLINE | ID: mdl-37460180

RESUMO

Objective: To investigate the effectiveness of anterior cruciate ligament (ACL) reconstruction assisted by personalized femoral locator based on the apex of deep cartilage (ADC) combined with patient imaging data. Methods: Between January 2021 and January 2022, a total of 40 patients with primary ACL rupture were selected and randomly divided into study group (ACL reconstruction assisted by personalized femoral locator based on ADC) and control group (ACL reconstruction assisted by intraoperative fluoroscopy and traditional femoral locator), with 20 cases in each group. There was no significant difference in gender, age, body mass index, affected side, cause of injury, and preoperative International Knee Documentation Committee (IKDC) score, Lyshlom score, and Tegner score between the two groups ( P>0.05). IKDC score, Lyshlom score, and Tegner score were used to evaluate the functional recovery of the affected knee before operation and at 3, 6, and 12 months after operation. CT scan and three-dimensional reconstruction were performed before and after operation to measure the horizontal distance from ADC to the anterior cartilage margin (L) and the horizontal distance from ADC to the center of the femoral canal (I), and the anteroposterior position of the bone canal (R) was calculated by I/L; the distance from the center to the distal cartilage margin (D) was measured on the two-dimensional cross section; the R value and D value were compared between the two groups. Results: The operation time of the study group was significantly less than that of the control group [ MD=-6.90 (-8.78, -5.03), P<0.001]. The incisions of the two groups healed by first intention, and no complication such as intra-articular infection, nerve injury, and deep vein thrombosis of lower limbs occurred. There was no significant difference in the R value and D value between the preoperative simulated positioning and the actual intraoperative positioning in the study group [ MD=0.52 (-2.85, 3.88), P=0.758; MD=0.36 (-0.39, 1.11), P=0.351]. There was no significant difference in the actual intraoperative positioning R value and D value between the study group and the control group [ MD=1.01 (-2.57, 4.58), P=0.573; MD=0.24 (-0.34, 0.82), P=0.411]. The patients in both groups were followed up 12-13 months (mean, 12.4 months). The IKDC score, Lysholm score, and Tegner score of the two groups increased gradually with time, and there were significant differences between pre- and post-operation ( P<0.05). There was no significant difference in the scores between the two groups at each time point after operation ( P>0.05). Conclusion: The personalized femoral locator based on ADC can accurately assist the femoral tunnel positioning in ACL reconstruction, which can shorten the operation time when compared with traditional surgical methods, and achieve satisfactory early effectiveness.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Cartilagem/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Resultado do Tratamento
3.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(6): 663-669, 2023 Jun 15.
Artigo em Chinês | MEDLINE | ID: mdl-37331940

RESUMO

Objective: To investigate the changes of knee joint kinematics after anterior cruciate ligament (ACL) reconstruction assisted by personalized femoral positioner based on the apex of deep cartilage (ADC). Methods: Between January 2021 and January 2022, a total of 40 patients with initial ACL rupture who met the selection criteria were randomly divided into the study group (using the personalized femoral positioner based on ADC design to assist ACL reconstruction) and the control group (not using the personalized femoral positioner to assist ACL reconstruction), with 20 patients in each group. Another 20 volunteers with normal knee were collected as a healthy group. There was no significant difference in gender, age, body mass index, and affected side between groups ( P>0.05). Gait analysis was performed at 3, 6, and 12 months after operation using Opti _ Knee three-dimensional knee joint motion measurement and analysis system, and the 6 degrees of freedom (flexion and extension angle, varus and valgus angle, internal and external rotation angle, anteroposterior displacement, superior and inferior displacement, internal and external displacement) and motion cycle (maximum step length, minimum step length, and step frequency) of the knee joint were recorded. The patients' data was compared to the data of healthy group. Results: In the healthy group, the flexion and extension angle was (57.80±3.45)°, the varus and valgus angle was (10.54±1.05)°, the internal and external rotation angle was (13.02±1.66)°, and the anteroposterior displacement was (1.44±0.39) cm, the superior and inferior displacement was (0.86±0.20) cm, and the internal and external displacement was (1.38±0.39) cm. The maximum step length was (51.24±1.29) cm, the minimum step length was (45.69±2.28) cm, and the step frequency was (12.45±0.47) step/minute. Compared with the healthy group, the flexion and extension angles and internal and external rotation angles of the patients in the study group and the control group decreased at 3 months after operation, and the flexion and extension angles of the patients in the control group decreased at 6 months after operation, and the differences were significant ( P<0.05); there was no significant difference in the other time points and other indicators when compared with healthy group ( P>0.05). In the study group, the flexion and extension angles and internal and external rotation angles at 6 and 12 months after operation were significantly greater than those at 3 months after operation ( P<0.05), while there was no significant difference in the other indicators at other time points ( P>0.05). There was a significant difference in flexion and extension angle between the study group and the control group at 6 months after operation ( P<0.05), but there was no significant difference of the indicators between the two groups at other time points ( P>0.05). Conclusion: Compared with conventional surgery, ACL reconstruction assisted by personalized femoral positioner based on ADC design can help patients achieve more satisfactory early postoperative kinematic results, and three-dimensional kinematic analysis can more objectively and dynamically evaluate the postoperative recovery of knee joint.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Amplitude de Movimento Articular , Cartilagem/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...